APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21164 Issued:2001-07-28
Revised:2019-12-13
Style 21164 Multiconductor Cable with Extruded Non- Integaral Jacket.

Rating80 deg C, 150 Vac, Horizontal flame.
ConductorMin. 40 AWG solid or stranded round.
InsulationLabeled or complies with manufacturer`s AWM Procedure.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable.Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
JacketTPU*
diameter of cable under jacket in inchMinimum average thicknessMinimum thickness at any point
0.425 or less45 mils36 mils
0.426-0.70060 mils48 mils
0.701-1.50080 mils64 mils
1.501-2.500110 mils88 mils
2.501 and larger140 mils112 mils
* - Major diameter if cable is flat or oval.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseAs internal wiring of equipment.