APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21168 Issued:2001-09-06
Revised:2012-05-29
Style 21168 Flat Cable.

Rating60 or 80 deg C, 30 Vac, Horizontal flame.
Conductor50 AWG - 2000 kcmil. Solid or stranded round.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyMulti conductors laid parallel, same or mixed AWG.
CoveringExtruded PVC, 4 mils minimum thickness at any point, with or without an interconnecting web. Minimum thickness of web not specified.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.