APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21170 Issued:2001-09-24
Revised:2019-11-07
Style 21170 Multiple-conductor cable with non-integral jacket

Rating60 deg C, 1000 Vac, Cable flame.
InsulationLabeled or complying with Manufacturer's AWM Procedure.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
CoveringOptional. A 6 mil or heavier PVC covering may be extruded over the conductor assembly.
JacketPVC
major dia. in inches
0.700 or less30 mils min average24 mils minimum at any point
0.701-1.000 dia60 avg48 min
1.001-1.500 dia80 avg64 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal or External Wiring.