| Rating | 250 deg C, 150 Vac, Horizontal flame. |
|
| Conductor | 30 AWG - 18 AWG Resistance Wire, Nickel-coated copper, Nickel or Nickel alloy wire, solid or stranded. |
|
| Insulation | Extruded PFA, 10 mils min average, 9 mils minimum at any point. |
|
| Assembly | Twisted pair, length of lay not specified. |
|
| Covering | Optional. Kapton tape, minimum thickness 2 plus or minus 1 mil, Minimum overlap 50%. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Internal wiring Where Not Subjected to Movement or Mechanical abuse. |
|