APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21171 Issued:2001-10-10
Revised:2013-03-28
Style 21171 Multiconductor with extruded insulation

Rating250 deg C, 150 Vac, Horizontal flame.
Conductor30 AWG - 18 AWG Resistance Wire, Nickel-coated copper, Nickel or Nickel alloy wire, solid or stranded.
InsulationExtruded PFA, 10 mils min average, 9 mils minimum at any point.
AssemblyTwisted pair, length of lay not specified.
CoveringOptional. Kapton tape, minimum thickness 2 plus or minus 1 mil, Minimum overlap 50%.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring Where Not Subjected to Movement or Mechanical abuse.