Rating | 80 deg C, 300 Vac, Horizontal flame. |
|
Conductor | 30 AWG - 10 AWG solid or stranded round. |
|
Insulation | Labeled or Complying with manufacturers Procedure or Extruded PE or Extruded Foamed PE or Extuded FRPE or Extruded Foamed FRPE |
| AWG conductor size | Minimum Average Thickness in mils | Minimum Thickness at any point in mils |
| 30-16 | 15 | 13 |
| 15-10 | 20 | 18 |
|
Assembly | Two or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer (polyester tape) and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Shield | Inner and outer shield are optional. |
|
Covering | Optional. a textile braid, nylon jacket (2 mils minimum thickness), or minimum 8 mils of semi-rigid or regular PVC may be applied between the conductor assembly and shield. |
|
Jacket | Extruded PVC, 15 mils min average, 12 mils minimum at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring. |
|