APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21185 Issued:2002-01-07
Revised:2012-04-23
Style 21185 Multiple-conductor cable using non-integral jacket.

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor30 AWG - 10 AWG solid or stranded round.
InsulationLabeled or Complying with manufacturers Procedure or Extruded PE or Extruded Foamed PE or Extuded FRPE or Extruded Foamed FRPE
AWG conductor sizeMinimum Average Thickness in milsMinimum Thickness at any point in mils
30-161513
15-102018
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer (polyester tape) and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldInner and outer shield are optional.
CoveringOptional. a textile braid, nylon jacket (2 mils minimum thickness), or minimum 8 mils of semi-rigid or regular PVC may be applied between the conductor assembly and shield.
JacketExtruded PVC, 15 mils min average, 12 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024