Rating | 60 deg C, 300 Vac, Cable flame. |
|
Insulated conductors | Labeled or complying with manufacturer's AWM Procedure having a minimum rating of 60 deg C and 300 V. |
|
Assembly | Two or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Covering | Optional. A 6 mil or heavier PVC covering may be extruded over the conductor assembly. |
|
Shield | Optional. |
|
Jacket | PVC. |
| Dia. of round assembly under jacket in inches | Minimum average thickness (mils) | Minimum thickness at any point (mils) |
| 0.7 or less | 30 | 24 |
| 0.701 - 1.000 | 45 | 36 |
| 1.001 - 1.500 | 60 | 48 |
| 1.501 - 2.500 | 80 | 64 |
| 2.501 - 4.000 | 110 | 88 |
| 4.001 or larger | 140 | 112 |
| # Major dia if cable is flat or oval. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring or external interconnection of electronic equipment (such as desk-type calculators, dictating machines, or x-ray equipment). |
|