APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21195 Issued:2002-01-31
Revised:2012-01-05
Style 21195 Multiconductor Cable with Extruded Non-Integral Jacket.

Rating150 deg C, 600 Vac, Cable flame.
Conductor40 AWG minimum.
InsulationLabeled or complying with Manufacturer's AWM Procedure.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the insulated conductors are not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
FillerFillers - (Optional) Single or mixed fillers consisting of ETFE, PFA, FEP, Foamed PTFE, PTFE, or glass.
Tape(Optional) ETFE, PFA, FEP, Cellular PTFE, PTFE, or glass cloth.
CoveringOptional. 10 mils or heavier extruded PFA or FEP, or 15 mils or heavier extruded ETFE covering may be extruded over the conductor assembly.
ShieldOptional.
JacketExtruded PFA.
Dia. under jacket in inchesMinimum Average Thickness - MilsMinimum at any point Thickness - Mils
0.350 or less108
0.351 - 0.5001310
0.501 - 0.7001512
0.701 - 1.502016
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024