Rating | 150 deg C, 600 Vac, Cable flame. |
|
Conductor | 40 AWG minimum. |
|
Insulation | Labeled or complying with Manufacturer's AWM Procedure. |
|
Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the insulated conductors are not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Filler | Fillers - (Optional) Single or mixed fillers consisting of ETFE, PFA, FEP, Foamed PTFE, PTFE, or glass. |
|
Tape | (Optional) ETFE, PFA, FEP, Cellular PTFE, PTFE, or glass cloth. |
|
Covering | Optional. 10 mils or heavier extruded PFA or FEP, or 15 mils or heavier extruded ETFE covering may be extruded over the conductor assembly. |
|
Shield | Optional. |
|
Jacket | Extruded PFA. |
| Dia. under jacket in inches | Minimum Average Thickness - Mils | Minimum at any point Thickness - Mils |
| 0.350 or less | 10 | 8 |
| 0.351 - 0.500 | 13 | 10 |
| 0.501 - 0.700 | 15 | 12 |
| 0.701 - 1.50 | 20 | 16 |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring or external interconnection of electronic equipment. |
|