APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21196 Issued:2002-01-31
Revised:2019-11-07
Style 21196 Multiple-Conductor Cable using Non-Integral Jacket.

Rating150 deg C, 600 Vac, Cable flame.
Conductor40 AWG minimum.
InsulationLabeled or complying with Manufacturer's AWM Procedure.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the insulated conductors are not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. Fillers - (Optional) Single or mixed fillers consisting of ETFE, PFA, FEP, Cellular PTFE, PTFE, or glass.
ShieldOptional.
CoveringOptional. 10 mils or heavier PFA or FEP, or 15 mils or heavier ETFE covering may be extruded over the conductor assembly. Tape(Optional, over fillers) ETFE, PFA, FEP, Cellular PTFE, PTFE, or glass cloth.
JacketExtruded FEP
dia. in inches
0.350 or less10 mils min average8 mils minimum at any point
0.351-0.500 dia13 avg10 min
0.501-0.700 dia15 avg12 min
0.701-1.500 dia20 avg16 min
Misc.Fillers (Optional) Single or mixed fillers consisting of ETFE, PFA, FEP, Cellular PTFE, PTFE, or glass.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024