Rating | 150 deg C, 600 Vac, Cable flame. |
|
Conductor | 40 AWG minimum. |
|
Insulation | Labeled or complying with Manufacturer's AWM Procedure. |
|
Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the insulated conductors are not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. Fillers - (Optional) Single or mixed fillers consisting of ETFE, PFA, FEP, Cellular PTFE, PTFE, or glass. |
|
Shield | Optional. |
|
Covering | Optional. 10 mils or heavier PFA or FEP, or 15 mils or heavier ETFE covering may be extruded over the conductor assembly. Tape(Optional, over fillers) ETFE, PFA, FEP, Cellular PTFE, PTFE, or glass cloth. |
|
Jacket | Extruded FEP |
| dia. in inches |
| 0.350 or less | 10 mils min average | 8 mils minimum at any point |
| 0.351-0.500 dia | 13 avg | 10 min |
| 0.501-0.700 dia | 15 avg | 12 min |
| 0.701-1.500 dia | 20 avg | 16 min |
|
Misc. | Fillers (Optional) Single or mixed fillers consisting of ETFE, PFA, FEP, Cellular PTFE, PTFE, or glass. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring or external interconnection of electronic equipment. |
|