Rating | 150 deg C, 600 Vac, Cable flame. |
|
Conductor | 40 AWG minimum. |
|
Insulation | Labeled or complying with Manufacturer's AWM Procedure. |
|
Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the insulated conductors are not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Fillers | Optional. Single or mixed fillers consisting of ETFE, PFA, FEP, Cellular PTFE, PTFE, or glass. |
|
Tape | Optional. ETFE, PFA, FEP, Cellular PTFE, PTFE, or glass cloth. |
|
Covering | Optional. 10 mils or heavier PFA or FEP, or 15 mils or heavier ETFE covering may be extruded over the conductor assembly. Tape (Optional, over fillers) ETFE, PFA, FEP, Cellular PTFE, PTFE, or glass cloth. |
|
Shield | Optional. |
|
Jacket | Extruded ETFE |
| Diameter under jacket in inches | Minimum average thickness | Minimum thickness at any point |
| 0.700 inch or less | 15 mils | 12 mils |
| 0.701 - 1.500 inch | 20 mils | 16 mils |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring or external interconnection of electronic equipment. |
|