Style 21200 Multiple conductor with extruded insulation.

Rating90 deg C, 300 Vac, FT1 flame.
Conductor20 AWG - 18 AWG, solid or stranded.
InsulationExtruded PVC, 30 mils minimum average thickness, 27 mils minimum thickness at any point. May be Labeled or complying with Maunfacturer's AWM Procedure.
AssemblyMulti conductors, same as type SPT-2 Cord with an overall cotton or rayon braid.
BraidCotton or Rayon.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseSpecial purpose power supply cord for lamps where the acceptability of the combination is to be determined by Underwriters Laboratories Inc.