APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21207 Issued:2002-03-06
Revised:2012-10-16
Style 21207 Multiple-conductor cable using non-integral jacket

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor22 AWG solid, tinned or bare.
Insulated ConductorLabeled or complying with manufacturer's AWM procedure.(style 1064) 16 mils min average, 14 mils minimum at any point.
AssemblySeven insulated conductors cabled together with overall jacket.
JacketTPE, 46 mils min average, 37 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseWiring connections to a moving part in Electric Battery Powered Industrial Trucks.