APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21209 Issued:2002-03-27
Revised:2012-04-25
Style 21209 Multiple-conductor cable using non-integral jacket.

Rating90 deg C, 125 Vac, 150 Vac, 300 Vac, 600 Vac or 1000 Vac, Cable flame.
Conductor40 AWG min. solid or stranded round.
InsulationLabeled or complies with manufacturer's Singles AWM Procedure rated 90 deg C min and a voltage rating equaling or exceeding the rating of the cable.
AssemblyTwo or more singles or groups of twisted singles twisted together. Lay not specified. Barrier layer, shield, braid and/or fillers optional.
JacketExtruded TPU -
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.700 inch or less30 mils24 mils
0.701-1.000 inch45 mils36 mils
1.001-1.500 inch60 mils48 mils
1.501-2.500 inch80 mils64 mils
2.501-4.500 inch110 mils88 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal or external wiring.

UL and the UL Logo are trademarks of UL LLC © 2024