Rating | 90 deg C, 125 Vac, 150 Vac, 300 Vac, 600 Vac or 1000 Vac, Cable flame. |
|
Conductor | 40 AWG min. solid or stranded round. |
|
Insulation | Labeled or complies with manufacturer's Singles AWM Procedure rated 90 deg C min and a voltage rating equaling or exceeding the rating of the cable. |
|
Assembly | Two or more singles or groups of twisted singles twisted together. Lay not specified. Barrier layer, shield, braid and/or fillers optional. |
|
Jacket | Extruded TPU - |
| Diameter of core assembly under jacket | Minimum average thickness | Minimum thickness at any point |
| 0.700 inch or less | 30 mils | 24 mils |
| 0.701-1.000 inch | 45 mils | 36 mils |
| 1.001-1.500 inch | 60 mils | 48 mils |
| 1.501-2.500 inch | 80 mils | 64 mils |
| 2.501-4.500 inch | 110 mils | 88 mils |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal or external wiring. |
|