APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2121 Issued:1959-05-01
Revised:2012-04-18
Style 2121 Single conductor wire using non-integral jacket.

Rating90 deg C, 300 Vac (Insulation), 600 Vac (Jacket), Horizontal Flame.
Conductor26 AWG - 16 AWG, solid or stranded.
InsulationExtruded PVC, 15 mils minimum average thickness, 14 mils minimum thickness at any point.
AssemblyTwo Conductors.
ShieldShielding over one or both conductors shall consist of Nos. 36 AWG - 30 AWG, tinned or untinned, copper strands applied as a wrap or braid.
CoveringLacquered Braid.
JacketExtruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UsePhonograph pick-up and Volume Control.

UL and the UL Logo are trademarks of UL LLC © 2024