APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21210 Issued:2002-04-26
Revised:2012-03-30
Style 21210 Multiple-Conductor Cable Using Extruded Non-Integral Jacket

Rating80 deg C, 30 Vac, Horizontal flame.
Conductor40 AWG minimu, solid or stranded round, tinned or bare.
InsulationLabeled or complying with Manufacturer's AWM Procedure.
AssemblyTwo or more singles, twisted pairs or groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
JacketExtruded PUR/PVC blend, 5 mils minimum average thickness, 3 mils minimum thickness at any point. If parallel construction is rippable, the measurements are made after ripping.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment.