APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21214 Issued:2002-04-26
Revised:2012-04-18
Style 21214 Multiple-conductor cable using non-integral jacket

Rating80 deg C, 300 Vac, Cable flame.
Insulated ConductorLabeled or complying with Manufacturer's AWM Procedure.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
CoveringOptional. Extruded PVC, over the conductor assembly, 6 mils minimum thickness at any point.
JacketExtruded PVC/TPU.
Dia. of cable under jacket@Minimum average thicknessMinimum thickness at any point
0.700 inch or less30 mils24 mils
0.701-1.000 inch60 mils48 mils
1.001-1.501 inch80 mils64 mils
@ - Major diameter if cable is flat or oval.
BraidOptional.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal wiring or internal wiring.