APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21215 Issued:2002-04-26
Revised:2019-11-07
Style 21215 Jacketed Cord.

Rating80 deg C, 600 Vac, Cable flame.
Conductor32 AWG - 12 AWG solid or stranded round, tinned or bare copper.
InsulationLabeled or complying with Manufacturer's AWM Procedure.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or singles or groups of singles may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
CoveringOptional. A 6 mil or heavier PVC covering may be extruded over the conductor assembly.
JacketPUR/PVC
major dia. in inches
0.700 or less30 mils min average24 mils minimum at any point
0.701-1.000 dia60 avg48 min
1.001-1.501 dia80 avg64 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnect or internal wiring of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024