Rating | 80 deg C, 300, 600, 1000 Vac, Cable flame. |
|
Conductor | 40 AWG min. solid or stranded round, tinned or bare copper. |
|
Insulation | Labeled or complying with manufacturer's AWM Procedure. |
|
Assembly | Consists of one or more conductors or groups of conductors twisted together. The conductors or groups of conductors may be laid to form anoval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. |
|
Braid | Optional. Copper tinned or bare, with minimum coverage of percent. |
|
Jacket | TPE |
| Dia of cable under jacket | Minimum average thickness | Minimum thickness at any point |
| 0.700 in or less | 30 mils | 24 mils |
| 0.701-1.000 in | 45 mils | 36 mils |
| 1.010-1.500 in | 60 mils | 48 mils |
| 1.501-2.500 in | 80 mils | 64 mils |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External interconnection or internal wiring of electronic equipment. |
|