| Rating | 105 deg C, 600 Vac, FT2 flame. |
|
| Conductor | 12 AWG, copper, stranding. |
|
| Insulation | Extruded PVC, 15 mils min average, 13 mils minimum at any point. |
|
| Assembly | Consists of five conductors laid parallel. The green grounding conductor is in the center. The insulated conductors have nylon jacket over, then overall jacket applied in such a manner that a web, min. 41 mils thick is formed which separates the grounding conductor from the circuit conductors on both sides of it, forming a flat cable. |
|
| Misc. | Extruded Nylon - 4 mils min over the PVC insulation. |
|
| Jacket | Extruded TPE, 75 mils min average, 60 mils minimum at any point. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | In the manufacture of Special Use Cord Sets where extra-hard-usage cord is required and where the acceptability of the combination is determined by Underwriters Laboratories Inc. |
|