APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21220 Issued:2002-05-31
Revised:2012-04-26
Style 21220 Multiple-Conductor Cable using Non-Integral Jacket.

Rating105 deg C, 600 Vac, FT2 flame.
Conductor12 AWG, copper, stranding.
InsulationExtruded PVC, 15 mils min average, 13 mils minimum at any point.
AssemblyConsists of five conductors laid parallel. The green grounding conductor is in the center. The insulated conductors have nylon jacket over, then overall jacket applied in such a manner that a web, min. 41 mils thick is formed which separates the grounding conductor from the circuit conductors on both sides of it, forming a flat cable.
Misc.Extruded Nylon - 4 mils min over the PVC insulation.
JacketExtruded TPE, 75 mils min average, 60 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseIn the manufacture of Special Use Cord Sets where extra-hard-usage cord is required and where the acceptability of the combination is determined by Underwriters Laboratories Inc.