APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21222 Issued:2002-05-29
Revised:2011-10-11
Style 21222 Multiple-conductor cable using non-integral jacket.

Rating75, 80, 90 or 105 deg C, 300 Vac, Cable flame.
Conductor40 AWG minimum, solid or stranded.
Insulationlabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more conductors or groups of conductors laid parallel or twisted forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. May use same or mixed AWG size.
CoveringOptional. Extruded PVC, 6 mils or heavier.
ShieldOptional.
JacketExtruded PVC.
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.700 inch or less30 mils24 mils
0.701-1.000 inch45 mils36 mils
1.001-1.501 inch60 mils48 mils
1.501-2.500 inch80 mils64 mils
- Major Diameter if cable is flat or oval
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection or internal wiring.