|
Rating | 75, 80, 90 or 105 deg C, 300 Vac, Cable flame. |
|
Conductor | 40 AWG minimum, solid or stranded. |
|
Insulation | labeled or complying with manufacturer's AWM Procedure. |
|
Assembly | Two or more conductors or groups of conductors laid parallel or twisted forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. May use same or mixed AWG size. |
|
Covering | Optional. Extruded PVC, 6 mils or heavier. |
|
Shield | Optional. |
|
Jacket | Extruded PVC. |
| Diameter of core assembly under jacket | Minimum average thickness | Minimum thickness at any point |
| 0.700 inch or less | 30 mils | 24 mils |
| 0.701-1.000 inch | 45 mils | 36 mils |
| 1.001-1.501 inch | 60 mils | 48 mils |
| 1.501-2.500 inch | 80 mils | 64 mils |
| - Major Diameter if cable is flat or oval |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External interconnection or internal wiring. |
|