APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21235 Issued:2002-10-28
Revised:2012-04-25
Style 21235 Multi-conductor cable using non-integral jacket.

Rating80 deg C, 300 Vac, Cable flame.
Conductor40 AWG min. solid or stranded.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyConsists of two or more conductors or groups of conductors twisted together. The conductors or groups of conductors may be laid to form an oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly.
BraidOptional. Copper, tinned or bare.
JacketExtruded TPE thickness.
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.700 inch or less30 mils24 mils
0.701-1.000 inch45 mils36 mils
1.001-1.500 inch60 mils48 mils
1.501-2.500 inch80 mils64 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection or internal wiring of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024