| Rating | 105 deg C, 600 Vac, Cable flame, Optional - 60 deg C Oil, 75 deg C wet |
|
| Conductor | 40 AWG minimum solid or stranded |
|
| Insulation | Labeled or complying with Manufacturer's AWM Procedure. R/C QMTT2 insulation material rated for 75 C water resistance for wet location |
|
| Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
| Shield | Optional |
|
| Covering | Optional - Extruded TPE,SRPVC, PVC, FEP, PFA, EP or Nylon; 6 mils minimum thickness at any point |
|
| Jacket | Extruded TPE |
| Diameter of core assembly under jacket | Minimum average thickness | Minimum thickness at any point |
| 0.700 inch or less | 30 mils | 24 mils |
| 0.701-1.000 inch | 60 mils | 48 mils |
| 1.001-1.500 inch | 80 mils | 64 mils |
| 1.501-2.500 inch | 110 mils | 88 mils |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General |
|
| Use | External interconnection or internal wiring of electronic equipment or appliances |
|