APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21238 Issued:2003-01-04
Revised:2012-04-24
Style 21238 Multiple conductor cable using non-integral jacket

Rating80 deg C, 600 Vac, Horizontal flame.
Insulated singlesNo. 32 AWG minimum. Labeled or complying with Manufacturer's AWM Procedure having a minimum rating of 80 deg C, 600 V.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductor is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
CoveringOptional. A 6 mil or heavier covering may be extruded over the conductor assembly.
ShieldOptional.
JacketPUR.
Dia. of round assembly under jacket in inchesMinimum average thickness (mils)Minimum thickness at any point (mils)
0.350 or less1512
0.351 - 0.7003024
0.701 - 1.0004536
1.001 - 1.5006048
# Major dia if cable is flat or oval.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment and appliances.