Rating | 200 deg C, 150 Vac, Cable flame. |
|
Insulation | Labeled or complying with manufacturer's AWM Procedure. |
|
Assembly | Two insulated singles laid parallel, two to 40 of insulated singles twisted together, or one to 20 twisted pairs twisted together to form a round core assembly. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Shield | Optional, tinned or untinned copper wire braided. |
|
Jacket | FEP |
| dia. in inches |
| 0.250 or less | 12 mils min average | 10 mils minimum at any point |
| 0.251-0.350 dia | 14 avg | 11 min |
| 0.351-0.500 dia | 16 avg | 12 min |
| 0.501-0.700 dia | 18 avg | 14 min |
| 0.701-1.500 dia | 24 avg | 19 min |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal Wiring or External Interconnection of Electronic Equipment. |
|