APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21243 Issued:2003-01-22
Revised:2019-11-07
Style 21243 Multiple-conductor cable using non-integral jacket.

Rating200 deg C, 300 Vac, Cable flame.
InsulationLabeled or complying with manufacturer's AWM Procedure. Designations of all styles of individual conductors used in making up the cable assembly shall be available.
AssemblyTwo or more individually insulated conductors or coaxial members, or groups of insulated conductors cabled together to form a round cable. Glass fiber fillers may be used in a cable but are not required. A barrier layer, if employed, may be a PTFE or equivalent tape wrap. Such a barrier layer would serve to protect the cable during further processing, and would be applied immediately over the twisted assembly or individual conductors or groups of conductors.
ShieldOptional.
JacketExtruded PFA
dia. in inches
0.250 or less8 mils min average6 mils min at any point
0.251-0.350 dia10 avg8 min
0.351-0.500 dia13 avg10 min
0.501-0.700 dia15 avg12 min
0.701-1.500 dia20 avg16 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring or External Interconnection of Electronic Equipment.