APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21245 Issued:2003-01-31
Revised:2019-11-07
Style 21245 Multlple-conductor cable using non-intrgral jacket

Rating125 deg C, 300 Vac, Horizontal flame.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more individually insulated conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. The length of lay of the twisted conductors or groups is not specified. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or thermoplastic-tape wrap. Such a barrier would serve to protect the cable during further processing and would be applied immediately over the twisted assembly of individual conductors or groups of conductors.
ShieldOptional.
JacketETFE
dia. in inches
0.425 or less15 mils min average12 mils minimum at any point
0.426-0.700 dia30 avg26 min
0.701-1.500 dia45 avg40 min
1.501-2.500 dia60 avg55 min
2.501 dia and larger90 avg82 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.