APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21250 Issued:2003-02-21
Revised:2012-01-17
Style 21250 Multi-conductor cable using non-integral jacket.

Rating105 deg C, 600 Vac, Cable flame.
Conductor20 AWG - 10 AWG, solid or stranded.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyConsists of three conductors, twisted together. The lay of the conductors is not specified. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
JacketExtruded PVC
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.700 inch or less30 mils24 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection of electronic equipment.