Rating | 60, 75, 80, 90 or 105 deg C, 30, 90, 150, 300 or 600 Vac, Horizontal flame. |
|
Conductor | 40 AWG - 10 AWG, solid or stranded. |
|
Insulation | Labeled or complying with the manufacturer's AWM Procedure. |
|
Assembly | Consists of three conductors, twisted together. The lay of the conductors is not specified. Fillers or tapes optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Shield | Optional. |
|
Covering | Optional. |
|
Jacket | Extruded PVC |
| diameter of core assembly under jacket | Min average thickness | Min thickness at any point |
| 0.15 inches or less | 10 mils | 9 mils |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of electronic equipment and appliances. |
|