APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2126 Issued:1959-05-01
Revised:2011-10-05
Style 2126 Multiconductor Cable with Extruded Non-Integral Jacket

Rating90 deg C, 600 Vac, Horizontal flame.
Conductor28 AWG - 9 AWG, solid or stranded round.
InsulationPVC, 31 mils min average, 28 mils minimum at any point.
AssemblyFour conductors.
ShieldOptional.
JacketPVC, 31 mils min average, 25 mils minimum at any point or a lacquered braid.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UsePhonograph Pick-Up and Volume Control or Internal Wiring of Appliances.

UL and the UL Logo are trademarks of UL LLC © 2024