APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21262 Issued:2003-04-25
Revised:2012-03-30
Style 21262 Multiple-Conductor Cable Using Extruded Non-Integral Jacket

Rating90 deg C, 600 Vac, FT2 flame.
ConductorSolid or stranded round, tinned or bare.
InsulationLabeled or complying with Manufacturer's AWM Procedure.
ShieldOptional - 1 mils minimum thickness or thicker PETP foil covering may be applied over the conductor assembly.
CoveringOptional- 4 mils minimum thickness or thicker wall of EPDM may be extruded over the conductor assembly or groups of conductors.
JacketExtruded EVA Rubber
Diameter of core assembly under jacket (inches)Minimum average thickness (mils)Minimum thickness at any point (mils)
0.750 or less5544
0.751-1.00011088
1.001-1.250125100
1.251-1.500140112
1.501-1.750160128
1.751-2.000180144
2.001-2.250200160
2.251-2.500220176
2.501-2.750240192
2.751-3.00260208
3.001-3.250280224
3.251-3.500295236
3.501-3.950310248
3.951-4.450330264
4.451-5.000345276
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.