APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21265 Issued:2003-05-13
Revised:2019-11-07
Style 21265 Multiconductor Cable with Extruded Non-integral Jacket.

Rating80 deg C, 300 Vac, Cable flame.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more individually insulated wires or group of individually insulated wires cabled together. Fillers may be used in a cable but are not required. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethyelene terephthalate; or thermoplastic-tape wrap. Such a barrier layer would serve to protect the cable during further processing and would be applied immediately over the twisted assembly of individual conductors or groups or conductors. May be formed in a round or flat assembly.
ShieldOptional.
JacketFRPE
major dia. in inches
0.700 or less30 mils min average24 mils minimum at any point
0.701-1.000 dia45 avg36 min
1.010-1.500 dia60 avg48 min
1.501-2.500 dia80 avg64 min
- Major diameter if cable is flat or oval.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal or External Wiring of Electronic Equipment.