APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21268 Issued:2003-05-14
Revised:2012-04-24
Style 21268 Laminated Flat Ribbon Cable.

Rating105 deg C, 300 Vac, Horizontal flame.
ConductorTwo to 100 conductors. 36 AWG - 4 AWG solid or stranded round or flat.
InsulationPETP film, 0.8 mil minimum thickness bonded each side of conductors, with Polyester adhesive, 0.5 mil minimum thickness, 10 mils minimum edge width and 7 mils minimum distance between conductors.
ShieldOptional.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment (such as and business machines) and appliances.

UL and the UL Logo are trademarks of UL LLC © 2024