|
Rating | 80 deg C, 125 Vac, Cable flame. |
|
Conductor | 30 AWG - 4/0 AWG solid or stranded round, tinned or bare copper. |
|
Insulation | Labeled or complying with Manufacturer's AWM Procedure. |
|
Assembly | Two or more insulated singles twisted together. Lay not specified. Fillers, Shields, Braids and/or barrier layers description of each assembly. |
|
Covering | (Optional) A 6 mil or heavier extruded FRPE covering may be extruded over the conductor assembly. |
|
Jacket | Extruded FRPE |
| major dia. in inches |
| 0.700 or less | 30 mils min average | 24 mils minimum at any point |
| 0.701-1.000 dia | 45 avg | 36 min |
| 1.010-1.500 dia | 60 avg | 48 min |
| 1.501-2.500 dia | 80 avg | 64 min |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External wiring of appliances. |
|