APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21271 Issued:2003-06-24
Revised:2011-11-15
Style 21271 Multiconductor Cable with Extruded Non-Integral Jacket.

Rating80 deg C, 30 Vac, Cable flame.
Conductor40 AWG min. solid or stranded.
InsulationLabeled or complying with Manufacturer¿s AWM Procedure having a minimum rating of 80 deg C, 30 Vac.
AssemblyConsists of two or more conductors or groups of Conductors twisted together. The conductors or groups of conductors may be laid to form an oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly.
JacketExtruded TPE, thickness in accordance with the table below.
Cable diameter (In.)Min. average Thickness (Mils)Min. thickness at any point (Mils)
0.00 - 0.4002420
0.401 - 0.7003024
0.701 - 1.5004536
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection or internal wiring of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024