APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21272 Issued:2003-08-13
Revised:2019-11-07
Style 21272 Multiple-Conductor Cable using Non-Integral Jacket.

Rating80 deg C, 90 Vac, Cable flame.
InsulationLabeled or complies with this Manufacturer's AWM Procedure.
AssemblyTwo or more insulated singles or groups of insulated singles cabled together to form a flat, oval or round assembly, with optional inner covering, optional inner shield, optional outer covering, optional outer shield and overall jacket. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly.
ShieldInner and outer shield are optional.
CoveringInner and outer covering are optional. A 6 mil or heavier PVC covering may be extruded over the conductor assembly.
JacketExtruded FRPE
mjor dia. in inches
0.700 or less30 mils min average24 mils minimum at any point
0.701-1.000 dia45 avg36 min
1.001-1.500 dia60 avg48 min
1.501-2.500 dia80 avg64 min
2.501-4.000 dia110 avg88 min
4.001 dia and larger140 avg112 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring and external interconnection of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024