APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21275 Issued:2003-08-22
Revised:2012-03-27
Style 21275 Multiple-conductor cable using non-integral jacket.

Rating105 deg C, 300 Vac, Horizontal flame, Optional - 60 deg C Wet.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyCable consists of an overall jacket, two or more 18 AWG to 10 AWG conductors and an optional member consisting of an optional TPE, an aluminum mylar with optional drain wire in contact with the metal portion of the tape or polyester tape cabled around two or more 24-16 AWG insulated conductors, an optional fiber optic conductor. Braid may be optionally applied over conductors and/or assemblies.
SeparatorOptional. Paper 2 mils thick maximum may be employed under the overall jacket.
FillerOptional. Kevlar, Jute or Polypropylene fillers may be employed in the interstices to make the cable round.
ShieldOptional.
JacketExtruded TPE
Dia. under jacket in inchesMinimum average thickness milsMinimum thickness at any point mils
1.000 or less4540
1.001-1.6006048
1.601-2.5008064
2.501-4.00011088
4.001 and larger140112
Misc.Separator - Paper with 2 mils thick maximum may be employed under the overall jacket. Fillers - Kevlar, Jute or Polypropylene fillers may be employed in the interstices to make the cable round.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseSpecial use outdoor power supply cord; 105 deg C dry and 60 deg C wet where the acceptability of the combination is to be determined by Underwriters Laboratories Inc.

UL and the UL Logo are trademarks of UL LLC © 2024