APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21279 Issued:2003-09-05
Revised:2011-10-26
Style 21279 Multiconductor cabel with non-integral jacket.

Rating80 deg C, 600 Vac, Horizontal flame.
Conductor40 AWG minimum, Solid or stranded.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturers shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional. Over one or more of the insulated conductors or between the conductor assembly and the optional covering.
CoveringOptional. Extruded FRPE or extruded PVC, 5 mil minimum average thickenss, 4 mils minimum thickness at any point. Covering over the conductor assembly.
JacketExtruded FRPE, 12 mils minimum average thickness, 10 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electrical equipment.