APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21280 Issued:2003-09-05
Revised:2012-03-30
Style 21280 Multi-conductor cable using non-integral jacket

Rating80 deg C, 1000 Vac, Horizontal flame.
Conductor40 AWG min. solid or stranded round.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturers shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional. Over one or more of the insulated conductors or between the conductor assembly and the optional covering.
CoveringOptional. A 5 mil or heavier Extruded FRPE or Extruded PVC covering over the conductor assembly.
JacketExtruded FRPE, 12 mils min average, 10 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024