APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21284 Issued:2003-09-05
Revised:2019-11-07
Style 21284 Multiple conductor cable using non-integral jacket.

Rating80 deg C, 30 Vac, Cable flame.
Conductor40 AWG min. solid or stranded round, tinned or bare copper.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturers shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional. Over one or more of the insulated conductors or between the conductor assembly and the optional covering.
CoveringOptional. A 5 mil or heavier FRPE or PVC covering over the conductor assembly.
JacketFRPE
dia. in inches
0.700 or less30 mils min average24 mils minimum at any point
0.701-1.000 dia45 avg36 min
1.001-1.500 dia60 avg48 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection.