APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21286 Issued:2003-09-05
Revised:2012-03-30
Style 21286 Multiple-Conductor Cable Using Extruded Non-Integral Jacket

Rating80 deg C, 300 Vac, Cable flame.
Conductor40 AWG minimum, solid or stranded round, tinned or bare.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturers shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional. Over one or more of the insulated conductors or between the conductor assembly and the optional covering.
CoveringOptional. A 5 mil minimum thickness or thicker FRPE or PVC covering may be extruded over the conductor assembly.
JacketExtruded FRPE
Diameter of core assembly under jacket (inches)Minimum average thickness (mils)Minimum thickness at any point (mils)
0.700 or less3024
0.701-1.0004536
1.001-1.5006048
Major diameter if cable is flat or oval
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection.