| Rating | 80 deg C, 125 Vac, Horizontal flame. |
|
| Conductor | 30 AWG - 20 AWG, solid or stranded. |
|
| Insulation | Extruded PE or FRPE, 12 mils minimum average thickness, 11 mils minimum thickness at any point. |
|
| Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
| Covering | Optional. Extruded FRPE, 6 mils minimum thickness at any point, over the conductor assembly. |
|
| Shield | Optional. |
|
| Jacket | Extruded FRPE. |
| Dia. of cable under jacket@ | Minimum average thickness | Minimum thickness at any point |
| 0.700 inch or less | 30 mils | 24 mils |
| 0.701-1.000 inch | 45 mils | 36 mils |
| 1.001-1.500 inch | 60 mils | 48 mils |
| @ - Major dia if cable is flat or oval |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Internal wiring. |
|