APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21293 Issued:2003-09-26
Revised:2019-11-07
Style 21293 Mltiple-conductor cable using non-integral jacket

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor36 AWG min, Solid or Stranded Round, metal coated or bare copper.
InsulationLabeled or complying with manufacturer's AWM Procedure. The designations of all styles of individual conductors used in making up the cable assembly shall be available.
AssemblyTwo or more individually insulated conductors or groups of insulated conductors cabled together to form a round cable. A flat or oval cable may also be constructed with not more than three rows of single conductors or groups of conductors. The length of lay of the twisted conductors or groups is not specified. Fillers may be used in a cable but are not required. A barrier layer, if employed, may be a fibrous wrap serving, or braid, paper, nylon, oriented polyethylene terephthalate, or thermoplastic-tape wrap. Such a barrier layer would serve to protect the cable during further processing and would be applied immediately over the twisted assembly of individual conductors or groups of conductors.
ShieldOptional.
CoveringOptional.
JacketExtruded TPU
major dia. in inches
0.350 or less15 mils min average12 mils minimum at any point
0.351-0.700 dia30 avg24 min
0.701-1.000 dia40 avg36 min
1.101-1.500 dia54 avg48 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.

UL and the UL Logo are trademarks of UL LLC © 2024