|
Rating | 105 deg C, 30 Vac, Horizontal flame. |
|
Conductor | 36 AWG min, solid or stranded. |
|
Insulation | Labeled or complying with manufacturer's AWM Procedure and having a min rating of 105 deg C. The designations of all styles of individual conductors used in making up the cable assembly shall be available. |
|
Assembly | Two or more individually insulated conductors or groups of insulated conductors cabled together to form a round cable. A flat or oval cable may also be constructed with not more than three rows of single conductors or groups of conductors. The length of lay of the twisted conductors or groups is not specified. Fillers may be used in a cable but are not required. A barrier layer, if employed, may be a fibrous wrap serving, or braid, paper, nylon, oriented polyethylene terephthalate, or thermoplastic-tape wrap. Such a barrier layer would serve to protect the cable during further processing and would be applied immediately over the twisted assembly of individual conductors or groups of conductors. |
|
Shield | Optional. |
|
Jacket | Extruded TPE. |
| Dia of Cable Under Jacket - In. | Min Average Thickness - Mils | Min At Any Point - Mils |
| 0.350 or less | 15 | 12 |
| 0.351 - 0.700 | 30 | 24 |
| 0.701 - 1.000 | 40 | 36 |
| 1.001 - 1.500 | 54 | 48 |
| - Major dia if cable is flat or oval. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring. |
|