APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21299 Issued:2003-09-26
Revised:2011-09-19
Style 21299 Multiple-conductor cable using non-integral jacket.

Rating105 deg C, 300 Vac, FT2 flame, Oil Resistant 60 deg C.
Conductor16 AWG - 10 AWG. Stranded.
InsulationExtruded TPE, 30 mils min average, 27 mils minimum at any point.
AssemblyMinimum Fourteen conductors, same as type SJE, individually insulated conductors Assemblyor groups of insulated conductors cabled together to form a round cable. The length of lay of the twisted conductors or groups is 9.0 inches. Fillers, if used, shall be twisted with the conductors to make the conductor assembly have a circular cross section. A separator medium, talc, may be provided under the jacket
JacketExtruded TPE.
Diameter of core assembly under jacketMinimum average thickessMinimum thickness at any point
0.551 - 0.900 inch80 mils64 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseSimilar to Type SJEO Flexible Cord.

UL and the UL Logo are trademarks of UL LLC © 2024