Rating | 105 deg C, 300 Vac, FT2 flame, Oil Resistant 60 deg C. |
|
Conductor | 16 AWG - 10 AWG. Stranded. |
|
Insulation | Extruded TPE, 30 mils min average, 27 mils minimum at any point. |
|
Assembly | Minimum Fourteen conductors, same as type SJE, individually insulated conductors Assemblyor groups of insulated conductors cabled together to form a round cable. The length of lay of the twisted conductors or groups is 9.0 inches. Fillers, if used, shall be twisted with the conductors to make the conductor assembly have a circular cross section. A separator medium, talc, may be provided under the jacket |
|
Jacket | Extruded TPE. |
| Diameter of core assembly under jacket | Minimum average thickess | Minimum thickness at any point |
| 0.551 - 0.900 inch | 80 mils | 64 mils |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Similar to Type SJEO Flexible Cord. |
|