Rating | 60, 75, 80, 90 or 105 deg C, 300 Vac, Horizontal flame, Optional - 60 deg C Wet, Optional - 60 deg C wet, Optional - Sunlight resistant. |
|
Conductor | 18 AWG - 10 AWG stranded, even sizes only. Stranding same as for Type SJT. |
|
Insulation | Extruded PVC. |
| Conductor AWG size | Minimum average mils | Minimum at any point mils |
| 18-12 | 30 | 27 |
| 10 | 45 | 40 |
| Wet rated cable shall use RC QMTT2 suitable for a minimum 60 deg C water resistance, or if proprietary water resistant PVC compound is used, see Facing Page for compound designation. |
|
Assembly | Two circuit conductor and one grounding conductor. Length of lay of insulated conductors shall not exceed the maximum specified in for Type SJT Cord. |
|
Shield | Over one or more insulated conductors, copper 85% minimum coverage employing 36-34 AWG strands. Alternatively, Aluminum Foil 100% coverage over the black and white conductor and 30% minimum coverage of a braided copper shield, 36-34, over the foil. |
|
Jacket | Extruded PVC |
| Conductor AWG size | Minimum average mils | Minimum at any point mils |
| 18-14 | 35 | 28 |
| 12 | 45 | 36 |
| 10 | 60 | 48 |
| Sunlight resistant cable shall use RC QMTT2 compound suitable for 720 hour sunlight resistance, or if proprietary sunlight resistant PVC compound is used, see Facing Page for compound designation. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | For use in Appliances where: Equivalence to hard service cord is required. Metallic shielding is required around the conductors. An insulation grade jacket is required. Optional - May be used outdoors if QMTT2 compounds are used. |
|