APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21306 Issued:2003-11-28
Revised:2012-03-30
Style 21306 Multi-conductor cable using non-integral jacket

Rating60 deg C, 300 Vac, Cable flame.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more twisted singles or groups of twisted singles twisted together or groups may be laid parallel to form flat, oval, or round cables. May use same or mixed AWG. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly.
ShieldOptional.
CoveringOptional.
JacketExtruded FRPE
Diameter under jacket (inches)Min average thickness (mils)Min thickness at any point (mils)
0.700 or less3024
0.701-1.0004536
1.001-1.5006048
1.501-2.5008064
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring and external interconnection.