APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21313 Issued:2004-03-01
Revised:2011-08-18
Style 21313 Multiple-Conductor Cable with Extruded Non-Integral Jacket

Rating60 deg C, 30 Vac, Cable flame
InsulationLabeled or complies with manufacturer's Procedure
AssemblyTwo or more twisted singles or groups of twisted singles twisted together or groups may be laid parallel to form flat, oval, or round cables. May use same or mixed AWG. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly.
ShieldOptional
CoveringOptional
JacketExtruded TPU, 15 mils minimum average thickness, 12 mils minimum thickness at any point
StandardAppliance Wiring Material UL 758.
MarkingGeneral
UseInternal wiring and external interconnection in Class 2 circuits of electronic equipment

UL and the UL Logo are trademarks of UL LLC © 2024