APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21314 Issued:2004-03-01
Revised:2012-04-24
Style 21314 Multiple conductor using non-integral jacket

Rating60 deg C, 90 Vac, Cable flame.
Insulated singlesLabeled or complies with manufacturer's Procedure with minimum rating of 60 deg C, 90 V.
AssemblyTwo or more twisted singles or groups of twisted singles twisted together or groups may be laid parallel to form flat, oval, or round cables. May use same or mixed AWG. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly.
CoveringOptional.
ShieldOptional.
JacketPUR.
Dia. of round assembly under jacket in inchesMinimum average thickness (mils)Minimum thickness at any point (mils)
0.400 or less2420
0.401 - 0.7003024
0.701 - 1.5004536
# Equivalent diameter of flat assembly = 1.1284 x (TW)0.5 where T is the thickness of the assembly under jacket,and W is the width of the assembly under jacket.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring and external interconnection of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024