Rating | 60 deg C, 90 Vac, Cable flame. |
|
Insulated singles | Labeled or complies with manufacturer's Procedure with minimum rating of 60 deg C, 90 V. |
|
Assembly | Two or more twisted singles or groups of twisted singles twisted together or groups may be laid parallel to form flat, oval, or round cables. May use same or mixed AWG. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. |
|
Covering | Optional. |
|
Shield | Optional. |
|
Jacket | PUR. |
| Dia. of round assembly under jacket in inches | Minimum average thickness (mils) | Minimum thickness at any point (mils) |
| 0.400 or less | 24 | 20 |
| 0.401 - 0.700 | 30 | 24 |
| 0.701 - 1.500 | 45 | 36 |
| # Equivalent diameter of flat assembly = 1.1284 x (TW)0.5 where T is the thickness of the assembly under jacket,and W is the width of the assembly under jacket. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring and external interconnection of electronic equipment. |
|