APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21315 Issued:2004-03-01
Revised:2019-11-07
Style 21315 Multiconductor Cable with Extruded Non-integral Jacket.

Rating60 deg C, 600 Vac, Cable flame.
InsulationLabeled or complies with manufacturer's Procedure.
AssemblyTwo or more twisted singles or groups of twisted singles twisted together or groups may be laid parallel to form flat, oval, or round cables. May use same or mixed AWG. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly.
CoveringOptional.
ShieldOptional.
JacketPUR
dia. in inches
0.700 or less30 mils min average24 mils minimum at any point
0.701-1.000 dia45 avg36 min
1.001-1.500 dia60 avg48 min
1.501-2.500 dia80 avg64 min
Equivalent diameter of flat assembly = 1.1284 x (TW)0.5 where T is the thickness of the assembly under jacket, and W is the width of the assembly under jacket.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring and external interconnection of electronic equipment.