APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 21316 Issued:2004-03-01
Revised:2012-04-18
Style 21316 Multiple-conductor cable using non-integral jacket

Rating60 deg C, 1000 Vac, Cable flame.
Insulated ConductorLabeled or complies with manufacturer's Procedure.
AssemblyTwo or more twisted singles or groups of twisted singles twisted together or groups may be laid parallel to form flat, oval, or round cables. May use same or mixed AWG. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly.
CoveringOptional.
ShieldOptional.
JacketExtruded TPU.
Dia. of cable under jacketMinimum average thicknessMinimum thickness at any point
0.700 inch or less30 mils24 mils
0.701-1.000 inch45 mils36 mils
1.001-1.500 inch60 mils48 mils
1.501-2.500 inch80 mils64 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring and external wiring.

UL and the UL Logo are trademarks of UL LLC © 2024