Rating | 80 deg C, 30 Vac, Cable flame. |
|
Insulation | Labeled or complies with manufacturer's Procedure. |
|
Assembly | Two or more twisted singles or groups of twisted singles twisted together or groups may be laid parallel to form flat, oval, or round cables. May use same or mixed AWG. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. |
|
Shield | Optional. |
|
Covering | Optional. |
|
Jacket | TPU, 15 mils min average, 12 mils minimum at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring and external interconnection in Class 2 circuits of electronic equipment. |
|